WebPossibly caused by a stalled or overloaded motor. The servos are turned off. Can be caused by running the axis into a mechanical stop, a short in the motor, or a short of one motor lead to ground. References Haas Alarms PDF by Haas Automation, Inc. Haas Alarm: 162 Y AXIS DRIVE FAULT WebApr 24, 2015 · You can see where the leads are daisy chained between all the drives and go to this small power supply. That might have died. The errors I got as this failure was getting worse, would switch to an A axis fault whenever I turned on the 4th axis, otherwise it would be the drive right beside that one.

B AXIS DRIVE FAULT - 58322 - Industry Support Siemens

WebOct 7, 2005 · As per HAAS service manual: X-Axis drive fault: Current in servo motor beyond limit. Stalled/Overloaded motor. Can be caused by running a short distance into … WebFeb 3, 2011 · I have a 1996 Haas VF2 and the x-axis faulted on an error code 161, which basically means the motor is being overloaded or grounded out. The table is not blocked and can easily be moved by spinning the ball screw. So, I removed the x-axis motor and found the connector box packed with black dust. I'm assuming this is from the brushes. bom melton forecast https://gmtcinema.com

Haas Alarm: 162 Y AXIS DRIVE FAULT - Helman CNC

WebHaas Alarm: 161 X AXIS DRIVE FAULT – Current in X servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned off. Can be caused by … WebSep 4, 2012 · Z-axis fault 163 over current - HELP PLEASE ... Really sounds like you blew one of the big transistors on the Z drive card. You A axis card may be compatible with your Z axis, but check before swapping. ... Two Haas VF-2's, Haas HA5C, Haas HRT-9, Hardinge CHNC 1, Bother HS-300 Wire EDM, BobCAD V23, BobCAD V28. 09-02-2012, … WebMar 29, 2010 · Picked up a vintage 1990 VF1 that has x axis issues. On initial zero return if the Y axis zeros before the x the machine errors out with 139. After twe ... VF1 x motor z fault ... the servo drive or both. Good luck. 03-29-2010, 02:24 AM #7. Fopec. View Profile View Forum Posts gnc new lenox

Haas Alarm: 193 B AXIS DRIVE FAULT - Helman CNC

Category:Rotary - Troubleshooting - Haas Service Manual

Tags:Haas x axis drive fault

Haas x axis drive fault

Rotary - Troubleshooting - Haas Service Manual

WebApr 4, 2024 · NOTE: These instructional videos show procedures that should be performed only by trained service technicians. If you don’t have the proper training you coul... WebHaas Delivered Price This price includes shipping cost, export and import duties, insurance, and any other expenses incurred during shipping to a location in France agreed with you …

Haas x axis drive fault

Did you know?

WebAlarm 164 A AXIS DRIVE FAULT. Alarm 187 B SERVO ERROR TOO LARGE. Alarm 188 B SERVO OVERLOAD. Alarm 193 B AXIS DRIVE FAULT . The feeds and speeds are too high for the work. Decrease the … WebFeb 7, 2012 · Tried turning the drive sprocket by hand and it had virtually siezed, so it was time to strip it all down and clean. Soon freed up all the workings, put in some new seals …

WebApr 21, 2024 · Axis motor power cables. Make sure there is a ferrite filter P/N 64-1252 installed in X, Y, Z axis motor power cables [1]. Spindle motor cables. Make sure there is a ferrite filter installed in the motor output of the vector drive. For a 40HP vector with 6 wire leads [1] use ferrite P/N 64-1254.

WebHaas Alarm: 162 Y AXIS DRIVE FAULT – (L) Current in Live Tooling servo motor beyond limit, (M) Current in Y servo motor beyond limit. Possibly caused by a stalled or … WebJun 7, 2024 · Go to the Diagnostic screen on the pendant. Go to the I/O tab. Use an M43 (Unclamp) M44 (Clamp) code in MDI mode to troubleshoot the switch that generates the alarm. Check the discrete input Tool Turret Unl. for Alarm 113, or T. Turret Locked for Alarm 114. Test the sensor: Hold a screwdriver in front of the sensor.

WebJan 31, 2024 · There are four versions of Haas amplifiers. 30A [1], 45A [2], 60A [3], and 90A [4]. All four operate the same way. Smart Amplifier assemblies are powered from the 320 VDC Bus from the Vector Drive assembly or Minimill Power Supply. They each have a red LED FAULT light, and a green LED POWER ON light to show the status of the amplifier.

WebHaas Alarm: 193 B AXIS DRIVE FAULT. Current in B servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned off. Running the axis … gnc new mexicoWebRotary - Troubleshooting - Haas Service Manual Rotary - Service Manual 1 - Rotary - Introduction 2 - Rotary - CNC Installation 3 - Rotary - CNC Removal 4 -Rotary - SCOL - Installation 5 - Rotary - Operation 6 - Rotary … gnc new riverWebJun 13, 2011 · Sinumerik 840di with siemens 611u drives. X,Y,Z,B and C axis. B axis rotates 180 degrees to -180 degrees, C axis turns 360 degrees to -360 degrees. I am getting a B axis drive fault when machining a deep lock pocket on a door. The B axis is around at -180 degrees so is cutting horizontally from left to right step by step getting … bommel teppichWebPoor or Improper Maintenance. CNC machines need to be carefully cleaned and lubricated on a regular basis — otherwise, problems can begin to arise. A lack of cleaning could lead to a buildup of dirt and debris. This might seem to be purely a hygiene issue, but it can have real implications in the machine’s output. gnc new ownerWebSolution. The program does not load. Make sure there is a percentage sign (%) at the top and bottom of the program. Make sure the program number starts with the letter "O" and … bom melville water forecastWebSep 5, 2012 · Solved the problem. After checking fuses one more time, I found one that checked OK when I had power on (didn't realize I had it on the first go around at … gnc newtonWebAlarm: 161 X AXIS DRIVE FAULT Haas Alarm Description: Current in X servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned … gnc new city