Required min echo rx interval
WebRequired Min Echo RX Interval. This is the minimum interval, in microseconds, between received BFD echo packets that this system is capable of supporting. If this value is zero, the transmitting system does not support the receipt of BFD echo packets. WebMar 31, 2024 · The interface-type, interface-number, and ip-address arguments are required because BFD support exists only for directly connected neighbors. ... 3 - Your Discr.: 5 Min …
Required min echo rx interval
Did you know?
WebIt's required minimum RX interval is 300msec and the received desired minimum TX interval from cp143 is 200msec. The greater value of 300msec is chosen and multiplied by … WebMar 26, 2024 · Async Rx Stats addr : 0x0 Echo Rx Stats addr : 0x0 ... Command that shows the BFD status history. ... Last punted pkt required_min_rx_interval 2000000, Last punted …
WebSep 6, 2024 · Run min-tx-interval interval. The minimum interval for sending BFD packets is set. By default, the minimum interval for sending BFD packets is 1000 ms. Run min-rx-interval interval. The minimum interval for receiving BFD packets is set. By default, the minimum interval for receiving BFD packets is 1000 ms. Run detect-multiplier multiplier WebDec 7, 2024 · Actual exam question from Cisco's 300-410. Question #: 345. Topic #: 1. [All 300-410 Questions] What is the minimum time gap required by the local system before …
WebDesired minimum TX interval Required minimum RX interval Required minimum Echo RX interval (The OCSBC does not implement the echo function.) The OCSBC does not support BFD's "Demand Mode". The OCSBC does not support BFD's "Echo function". The OCSBC supports BFD for both IPv4 and IPv6 WebRequired min RX interval: This is the minimum interval that the local system can support between receipt of BFD control packets. If you set this value to zero, the remote system …
WebJun 26, 2012 · Required Min RX Interval: This is the minimum interval, in microseconds, ... The Echo function has the advantage of truly testing only the forwarding path on the …
WebSep 9, 2024 · What is the minimum time gap required by the local system before putting a BFD control packet on the wire? A. Detect Mult B. Required Min Echo RX Interval C. Desired Min TX Interval D. Required Min RX Interval tricks stylo facileWebWhen echo mode is enabled, the desired minimum echo transmit interval and required minimum transmit interval values are taken from the bfd interval milliseconds min_rx milliseconds parameters, respectively. tricks snowboardWebJun 5, 2013 · Required Min Echo RX Interval: This is the minimum interval, in microseconds, between received BFD Echo packets that this system is capable of supporting. ... Required echo rx interval: 0 us, multiplier: 3, diag: None My discr: 2149908486, your discr: 68, state UP, D/F/P/C/A: 0/0/0/1/0 tricks sqlWebAuthors' Addresses Weiqiang Cheng China Mobile Beijing China Email: [email protected] Ruixue Wang China Mobile Beijing China Email: [email protected] Xiao Min (editor) ZTE Corp. Nanjing China Email: [email protected] Reshad Rahman Individual Kanata Canada Email: … tern gleam f1WebThe required minimum interval between the received BFD control packets. The default value is 300ms. ... After configured, BFD control packets are sent out at this required minimum … tricks solving rubik\u0027s cubeWeb· Required Min Echo Rx Interval — This is the minimum interval, in microseconds, between received BFD echo packets that this system is capable of supporting. If this value is zero, the transmitting system does not support the receipt of BFD echo packets. tricks storetricks stella donnelly chords